Davey Torrium2 TT45 Pressure Controller for Pump Shut-off Head 150 to 450 Kpa

$401.00 $319.00
Brand davey
Model TT45
Availability In Stock
General information

WHY CHOOSE the Davey Torrium®2 controller?

 

  1. Constant Flow and Even Water Pressure
  • To prevent annoying fluctuations in water temperature during showers, Torrium®2 uses its intelligence to provide households with constant flow to give even water pressure.
  • It does this with its innovative pressure and flow sensors to start the pump on a pressure drop and to stop it on low flow (~1 lpm). This avoids pump cycling when there is continuing household demand for water.
  • Quick Cut-in for Even Pressure
  • To give you strong pressure right from the start, Torrium®2 is designed to cut in quickly when it senses demand for water. It cuts in when the pressure has dropped to 80% of the previous top (shut-off) pressure. 
  • It uses its intelligence to automatically set this cut-in pressure each time the pump stops. In doing so, it allows the system to automatically accommodate for variations in pump performance or site conditions.
  • Adaptive Starting
  • Torrium®2 is clever enough to detect the difference between normal water demand and a small leak in the system, such as a dripping faucet or a leaking cistern. 
  • For very low flows, Torrium®2 automatically adapts to reduce the cut-in pressure, which can be as low as 50% of its last shut-off pressure. This significantly reduces pump cycling to improve consumer satisfaction with the system. 
  • If normal flow is required in the house (>0.5 lpm), Torrium®2 will sense this and revert to normal mode and initiate an immediate pump start. 
  • Easy Status Check 
  • To easily check the system status, Torrium®2 has three simple LED indicators:
    • Red LED - the system is in standby mode
    • Green LED - the pump is running 
    • Yellow LED – fault condition
  • Pressure Indicator Window 
  • Gives a quick guide to the system pressure
  • A colour band of mainly green indicates maximum pressure
  • Mainly red indicates low pressure
  • If the colour band moves slowly towards red this signifies a slow drop in pressure and may indicate a small leak.
  • Greater Hydraulic Performance
  • For better hydraulic performance to supply more pressure with less wasted energy, Torrium®2 has larger water pathways and no moving parts in the pathways. This performance versus loss equation is especially evident at higher flow rates.
  • Greater Reliability 
  • To diminish the likelihood of blockages, Torrium®2 is designed with no moving control parts within the water pathways giving greater reliability and performance with varying water quality.
  • Dry Run Protection and Auto Restart
  • To protect the pump from damage due to dry running, Torrium®2 stops the pump when it detects a loss of prime (no water supply) situation. 
  • To reduce system downtime, the Torrium®2 waits 5 minutes then goes into auto retry mode, whereby it will restart the pump to see if prime can be re-established automatically. 
  • An auto restart occurs at 5 minutes, 30 minutes, 1 hour, 2, 4, 8, 16 and 32 hours. 
  • Torrium®2 will also restart if it detects flow through the system (e.g. from mains water pressure returning with pressure boosting applications). 
  • Pump Protection – High Water Temperature Cut-out 
  • For added security and longer life, a water over-temperature cut-out provides a second level of protection against closed head operation and repetitive cycling. 
  • For water temperatures above 70°C Torrium®2 will shut the pump down and the amber LED will be lit. When the water temperature drops to below 60°C, the Torrium®2 will allow the pump to restart.
  • Pump Protection – Excessive Electrical Current
  • To protect the pump motor, Torrium®2 will shut the pump down and indicate a fault if it detects excessive electrical current being drawn. This occurs if the pump motor is subjected to locked rotor or if someone tries to manually override the Torrium®2 by continually holding in the prime button.
  • Corrosion and Scale Resistance
  • To allow Torrium®2 to be used with water of varying quality, its flow sensors are mounted on a high grade stainless steel plate with special anti-scaling electronic action, which only turns the flow sensors on during pump operation.
  • Extra Draw off Capacity
  • To accommodate small leaks and to reduce cycling, Torrium®2 has an in-built spring loaded accumulator for extra draw off capacity. A spring loaded accumulator means low maintenance as there is no need for a pressure vessel with its regular air charging and checking. 
  • For increased draw off, an optional pressure tank, up to 18 litres, can be mounted on the vertical outlet. 
  • Power Surge Protection for Torrium®2 
  • To protect the Torrium®2 controller from electrical surges and spikes, thus extending its life, it has an in-built metal oxide varistor (MOV). The status of the MOV can be checked in the viewing window on the back of the Torrium®2. The MOV is a sacrificial component and should it be consumed due to repeated power surges or spikes, it will almost always blacken the viewing port. This will indicate a non-warrantable Torrium®2 failure. 
  • Ease of Installation 
  • For ease of installation, the plumbing can be connected to either the vertical or the right angle discharge outlet, which can rotate a full 360°. 

Range:

TypeRecommended Pump Shut-off HeadMaximum System PressureMax Flow Rate
TT45 150 to 450 kPa 1000 kPa 200 lpm
TT70 450 to 700 kPa 1000 kPa 200 lpm

 

Spec & Features
  • Features and technical specification of the product. Please contact us for further information and specifics.
  • Maximum system pressure
    1000 kPa
  • Capacities to
    200 lpm
  • Recommended pump shut-off head range
    TT45 : 150 to 450 kPa TT70: 450 to 700 kPa
  • Maximum water temperature
    70 C
  • Minimum water temperature
    1 C
  • Phase
    Single
  • Hz
    50 / 60
  • Warranty
    2 Years
Ask a question